Around the world, researchers are working extremely hard to develop new treatments and interventions for COVID-19 with new clinical trials opening nearly every day. This directory provides you with information, including enrollment detail, about these trials. In some cases, researchers are able to offer expanded access (sometimes called compassionate use) to an investigational drug when a patient cannot participate in a clinical trial.
The information provided here is drawn from ClinicalTrials.gov. If you do not find a satisfactory expanded access program here, please search in our COVID Company Directory. Some companies consider expanded access requests for single patients, even if they do not show an active expanded access listing in this database. Please contact the company directly to explore the possibility of expanded access.
Emergency INDs
To learn how to apply for expanded access, please visit our Guides designed to walk healthcare providers, patients and/or caregivers through the process of applying for expanded access. Please note that given the situation with COVID-19 and the need to move as fast as possible, many physicians are requesting expanded access for emergency use. In these cases, FDA will authorize treatment by telephone and treatment can start immediately. For more details, consult FDA guidance. Emergency IND is the common route that patients are receiving convalescent plasma.
Search Tips
To search this directory, simply type a drug name, condition, company name, location, or other term of your choice into the search bar and click SEARCH. For broadest results, type the terms without quotation marks; to narrow your search to an exact match, put your terms in quotation marks (e.g., “acute respiratory distress syndrome” or “ARDS”). You may opt to further streamline your search by using the Status of the study and Intervention Type options. Simply click one or more of those boxes to refine your search.
Displaying 110 of 423Dascena
The purpose of this study is to prospectively evaluate a machine learning algorithm for the prediction of outcomes in COVID-19 patients.
Shahid Beheshti University of Medical Sciences
Moderate to severe cases of SARS-associated ARDS based on inclusion/ exclusion criteria and the decision made in multi- disciplinary team are treated with 0.5 Gy whole lung radiation.
Dr Sze-Yuan Ooi
This is a multi-site, prospective, non-randomised trial assessing the implementation of a smartphone application-based model of care for patients with COVID-19 infection managed in community isolation. We will recruit 2000 COVID +ve patients aged 18 years and over who are managed at home. The objective will be to describe the rates of avoidable presentations to ED and 30 day all case mortality per diagnosed COVID-19 case and to compare these to a propensity matched and synthetic control group.
Kanuni Sultan Suleyman Training and Research Hospital
Novel Coronavirus 2019 Disease (COVID-19) mortality is highly associated with viral pneumonia and its complications. Accurate and prompt diagnosis shown to be effective to improve outcome by providing early treatment strategies. While chest X-ray (CXR) and computerized tomography (CT) are defined as gold standard, given the advantage of being an ionized radiation free, practical technique point of care ultrasound (POCUS) is also reported as a diagnostic tool for COVID-19. There are limited studies regarding the importance of POCUS in diagnosis and review of COVID-19. Therefore the aim of this study is to evaluate the utility of bedside lung ultrasound on diagnosis of COVID-19 for patients admitted to emergency department .
Hamad Medical Corporation
The pandemic of a newly upcoming viral disease which is associated with COVID-19 puts the whole world's health system under pressure. Patients suffering from this disease mainly develop respiratory symptoms, which can lead to severe acute respiratory distress syndrome (ARDS) necessitating ICU, admission in 10-20% of the cases admitted to hospital. In addition to these symptoms, patients show lymphopenia, cardiac symptoms and altered coagulation profiles. Although those patients are treated in the ICU the mortality is up to 20% due to multiorgan failure. The aim of this study is to show non-inferiority of flow-controlled ventilation compared to standard (lung protective ventilation). Methods: After admission to the ICU, the patients will receive information about the study and informed consent will be taken. Upon reaching the criteria for moderate to severe ARDS (P/F ratio below 200 mmHg and PEEP above 5 cmH2O) the patients will be randomized. In the treatment group (group A) the ultra-thin ventilation tube will be placed through the existing tube. Then flow-controlled ventilation will be applied for 48 hours. In the other group (group B) ventilation will be performed according to the lung protective strategy. All other treatment will be unchanged. Data-collection will be started 1 hour after initiation of the study. Primary end point is PaO2.
Shanghai Asclepius Meditec Inc.
This study will evaluate the efficacy and safety of Hydrogen-Oxygen Generator with Nebulizer (model AMS-H-03) developed by Shanghai Asclepius Meditech Co., Ltd. as an adjuvant therapy for the patients with COVID-19 infected pneumonia in improving the clinical symptoms and reducing the incidence of severe pneumonia, as compared with the reference device of EverFlo Oxygen Concentrator (registration certificate No.: NMPA Registration Standard: 20162542389) manufactured by Respironics, Inc. US.
Caption Health, Inc.
Participants scheduled for for an echocardiogram (echo) and being evaluated for, or is positive for COVID-19 will be asked if they would be willing to have their echo done using a new software program on one of the hand-held ultrasound scanners. The new software program guides the investigator, or any other non-sonographer, to take the best possible pictures of the participants heart. The prior version of this software is already being used clinically and is FDA approved. The main reason for using the updated version is that it's faster and better in terms of guiding the user.
CW+ Charity
The study aims to see if participant deterioration due to suspected coronavirus in a designated location (e.g. hotel) can be identified sooner by wearing the sensor. If sick patients can be identified early, participants are more likely to have better outcomes; the study believes that the sensor can help us do this. The sensor measures heart rate, respiratory rate and temperature every 2 minutes and this can be reviewed by the clinical team looking after the participants.
Coalition for Epidemic Preparedness Innovations
This is an open-label trial to evaluate the safety, tolerability and immunological profile of INO-4800 administered by intradermal (ID) injection followed by electroporation (EP) using CELLECTRA® 2000 device in healthy adult volunteers.
Royal National Orthopaedic Hospital NHS Trust
Magnetic Expansion Control (MAGEC) growth rods are used in the surgical treatment of children with scoliosis; the primary constituent metal alloy in these is titanium. Since June 2019, the manufacturer has released two Urgent Field Safety Notices (FSN) relating to known issues with the function of the rods that increase the risk of early failure and unplanned revisions. The UK MHRA has issued two similar Medical Device Alerts (MDA) with the most recent MDA issued on 1st April 2020, stating that (1) MAGEC rods must not be implanted in the UK until further notice and (2) all patients already implanted with this device should be followed up as soon as is possible. At the time of writing, hospitals across the world are facing incredible challenges in dealing with the COVID-19 pandemic. Due to this, virtually all planned clinic visits for MAGEC rod patients and X-ray appointments have been postponed to help reduce the risk of the virus spreading. Recent retrieval studies have shown that mechanical wear and corrosion of these rods is common, with a risk that the debris generated is released into surrounding tissue. This wear and corrosion is thought to be the primary cause of implant failures and the underlying implant factors leading to the issuing of FSNs and MDAs. Whilst titanium is known to be highly biocompatible, the baseline and toxic levels of this alloy in biological fluids are poorly understood. Additionally, a better understanding of blood titanium levels in patients with MAGEC rods may enable this to become a biomarker of wear and corrosion of the rods. This may help surgeons identify earlier those patients who may develop implant related problems. Furthermore, in the current COVID-19 environment, a blood test to measure titanium levels may be one of the most suitable ways in which to continue patient monitoring (and identify those at greatest risk of implant related issues), in the absence of regular clinic visits. Previous work from the RNOH involved a similar study investigating patients with titanium hip implants.